應用吸溼速乾纖維提升R410A分離式空調機性能研究 An Application of Using Different Moisture-Absorbing and Quick-Drying Fabrics for Performance Improvement of R410A Split-type Air Conditioner |
指導教授: |
莫懷恩
Mo, Huai-En |
學位類別: |
碩士 Master |
系所名稱: |
工業教育學系 Department of Industrial Education |
論文出版年: | 2016 |
畢業學年度: | 104 |
語文別: | 中文 |
論文頁數: | 56 |
中文關鍵詞: | 分離式空調機 、吸溼速乾纖維 、性能係數 、能源效率比 |
英文關鍵詞: | Split-type Air Conditioner, Moisture-absorbing and quick-drying fabrics, Coefficient of performance (COP), Energy Efficiency Ratio (EER) |
DOI URL: | https://doi.org/10.6345/NTNU202204090 |
論文種類: | 學術論文 |
相關次數: | 點閱:158 下載:0 |
分享至: |
查詢本校圖書館目錄 查詢臺灣博碩士論文知識加值系統 勘誤回報 |
本研究旨在應用吸溼速乾纖維室外機外殼開通風孔為條件,藉由蒸發冷卻效果增進壓縮機外殼散熱,以藉此提升空調機性能,達成節能之目的。
分離式空調機經過實驗後,其性能係數提升12.69 %,能源效率比提升29.39 %。實驗結果顯示:壓縮機包覆纖維後,藉由纖維之吸溼速乾功能,可提升壓縮機散熱效果,並確實改善系統整體性能,進而達到節能的效益。
This study aims to apply fiber and open air hole to help heat radiate by promoting the cooling effect of compressor shell of evaporating and condensing process to increase performance of system, and be able to reach the purpose of energy saving.
It was found that, after the air conditioner compressor coated profiled fiber, the Coefficient of Performance (COP) is improved by 12.69%, and the EER is raised by 29.39%.. The results show: after the compressor cover fiber, with moisture wicking capabilities fibers, can improve the cooling effect of the compressor, and does improve overall system performance, thus achieving energy efficiency.
[1] “National Centers for Environmental Information (NCEI) Formerly Known as National Climatic Data Center (NCDC).” 2015. Accessed August 26, 2016. Cited from http://www.ncdc.noaa.gov/.
[2] 交通部中央氣象局. “中央氣象局全球資訊網.” July 18, 2016. Accessed August 26, 2016. 取自 http://www.cwb.gov.tw/V7/climate/climate_info/monitoring/monitoring_7.html.
[3] 經濟部統計處. “工業產銷存動態調查產品統計.” Accessed August 28, 2016. 取自http://dmz9.moea.gov.tw/gmweb/investigate/InvestigateDA.aspx.
[4] 經濟部能源局, Bureau of Energy, Ministry of Economic Affairs, and R O C. “能源統計年報.” February 1, 2012. Accessed August 28, 2016. 取自http://web3.moeaboe.gov.tw/ecw/business/content/ContentLink.aspx?menu_id=378.
[5] S. Peck, and J. Richie, “Green roofs and the urban heat island effect,” Buildings., Cedar Rapids, IA 4, 2009.
[6] 葉承翰,“應用吸濕速乾纖維提升R410A窗型空調機性能研究”,國立臺灣師範大學,碩士論文,2014年7月。
[7] 徐瑜璟,“雙面針織布蕊吸點組織的變化對織物吸濕排汗性能的影響”,輔仁大學,碩士論文,2007年10月。
[8] 章以慶、李貴琪、游輝仁、繆梅芬,“兩種吸濕排汗合成纖維與純棉纖維織物之人體動靜態舒適性研究”,實踐設計學報,第72-89頁,第5期,2011年10月。
[9] 李銘軒、李貴琪、張偉瑤、周勝賢,“不同吸濕排汗織物舒適性之比較”,華岡紡織期刊,第23-37頁,第16卷,第1期,2009年3月。
[10] J De Sousa, C Cheatham and M Wittbrodt, “The effects of a moisture-wicking fabric shirt on the physiological and perceptual responses during acute exercise in the heat,” Apply Ergonomics ., vol. 45, 1, no. 6, pp. 1447-1453, Aug. 2016.
[11] 劉于詮、蘇宣輔,“不同布料吸濕排汗特性比較之實作”,華人運動生物力學期刊,第226-228頁,第7期,2012年10月。
[12] J. U. Ahamed, R. Saidur, and H. H. Masjuki, “A review on exergy analysis of vapor compression refrigeration system,” Renewable and Sustainable Energy Reviews., vol. 15, no. 3, pp. 1593-1600, 2011.
[13] C. E. Vincent, M. K. Heun, “Thermo economic analysis & design of domestic refrigeration systems,” In Domestic use of energy conference., 2006.
[14] J. L. C. Fannou, C. Rousseau, L. Lamarche, and S. Kajl, “A comparative performance study of a direct expansion geothermal evaporator using R410A and R407C as refrigerant alternatives to R22,” Applied Thermal Engineering., vol. 82, no. 5, pp. 306-317, May. 2015.
[15] P. Martínez, J. Ruiz, C.G. Cutillas, P.J. Martínez, A.S. Kaiser and M. Lucas, “Experimental study on energy performance of a split air-conditioner by using variable thickness evaporative cooling pads coupled to the condenser.” Applied Thermal Engineering., vol. 105, pp. 1041-1050, Jul. 2016.
[16] Eduardo M. Barreira, Cezar O.R. Negrão and Christian J.L. Hermes, “Thermoeconomic analysis and optimization of residential split-type air conditionersOriginal Research Article.” Applied Thermal Engineering., vol. 50, pp. 629-636, Jan. 2013.
[17] C. Aprea , R. Mastrullo and C. Renno, “An analysis of the performance of vapor compression plant working both as a water chiller and heat pump using R22 and R417A, ” Applied Thermal EnginEERing., vol. 24, pp. 487-499, 2004.
[18] 沈嘉勇,“R410A窗型冷氣機節能之研究”,國立臺灣師範大學,碩士論文,2016年1月。
[19] Z. Lei, “Model-based optimization for vapor compression refrigeration cycle,” Energy ., vol. 55, pp. 392-402, 2013.
[20] 楊建裕、陳加偉、林福真,“冷凍空調節能技術發展規劃”,前瞻科技與管理,第25-40頁,第1卷,第2期,2011年11月。
[21] 謝文德、鍾弘道、張凱涵、王啓川,“冷凍冷藏系統熱回收文獻回顧”,冷凍空調與能源科技雜誌,第35-53頁,第65期,2010年10月。
[22] 李懿庭,“微型化蒸氣壓縮循環電子散熱系統研究”,臺灣大學機械工程學系,碩士論文,2009年1月。
[23] Y. T. Ge, S. A. Tassou, I. D. Santosa, K. Tsamos, “Design optimisation of CO2 gas cooler/condenser in a refrigeration system,” Applied Energy., vol. 160, no. 15, pp. 973-981, Dec. 2015.
[24] Y. Lu, Y. Wang, C. Dong, L. Wang, A. P. Roskilly, “Design and assessment on a novel integrated system for power and refrigeration using waste heat from diesel engine,” Applied Thermal Engineering., vol. 91, no. 5, pp. 591-599, Dec. 2015.
[25] X. Yang, L. Zhao, H. Li, Z. Yu, “Theoretical analysis of a combined power and ejector refrigeration cycle using zeotropic mixture,” Applied Energy., vol. 160, no. 15, pp. 912-919, Dec. 2015.