本論文以三台國內外知名品牌之室內送風機為樣本,進行改善風機整體噪音的研究,為了尋找所有可能的噪音源,在研究中我們將三台送風機之馬達互換,並更改吸音措施,以觀察、測試各配件對送風機整體噪音值的貢獻度,進而抑制噪音的產生與傳遞。以往的研究常將噪音分為結構噪音與氣動傳音兩種噪音源,本論文提出的方法是於送風機的回風口處加裝一只消音箱,重點是,可在不影響送風機效能之前提下,有效的抑制送風機之氣動噪音,使送風機整體的噪音量大為降低。
ABSTRACT
In this article, the noises generated by fan coils from the three major brands in the market were studied. To analyze and find out the possible sound sources, the sound attribution of different parts was measured. After several experiments, the authors inspect that the aero acoustic noise can be reduced by a silencer. Therefore, specific silencers were designed and installed at the inlet of fan. Experimental results demonstrate that the aero acoustic noise level can be reduced greatly by the specially designed inlet silencer.
Keyword: noise reduction, silencer, aero acoustic noise.
[1] 顧哲安, “筆記型電腦之風扇設計與振動分析”,國立成功大學機械工程研究所,碩士論文,2001年。
[2] 吳慶財, “前傾式離心扇之實驗設計”,國立台灣工業技術學院機械工程技術研究所,碩士論文,1993年。
[3] 許宏祺, “Pentium 4 筆記型電腦冷卻風扇之實驗研究”,國立台灣科技大學機械工程技術研究所,碩士論文,2001年。
[4] 楊俊欽, “高性能,低噪音衛浴排風扇之實驗研究”,國立台灣科技大學機械工程技術研究所,碩士論文,2003年。
[5] 呂水煙, “前傾式離心風機之減噪研究”,國立台灣工業技術學院機械工程技術研究所,碩士論文,1997年。
[6] 李森墉、林銘宏, “離心式風扇之振動及其散熱系統分析”,國立成功大學機械工程學系,碩士論文,2003年。
[7] 沈銘秋、陳文亮、邱煥男、陳玟瑞、王世傑、哈冀連,“桌上型電腦散熱風扇之性能與噪音研究”,中華民國燃燒學會第十五屆學術研討會,嘉義,2005年。
[8] 洪宗揚, “後傾式離心風機之噪音研究”,國立台灣工業技術學院,碩士論文,1996年。
[9] 陳世雄、李秉勣, “離心風扇舌尖外型對性能與噪音的影響”,國立成功大學航空太空工程研究所,碩士論文,2003年。
[10] 李棟、顧建明, “階梯蝸舌蝸殼的降噪分析和實驗”,流體機械月刊,2004年。
[11] 李炫秉, “聲強法在離心扇噪音診斷與控制之研究”,國立台灣科技大學,碩士論文,1994年。
[12] 工研院機械所IT IS報告,風扇專題研究,ITRIMI-151-S408(86), 1997。
[13] 廖家焜, “離心式鼓風機之流場與噪音研究”,國立清華大學動力機械所,碩士論文,1997年。
[14] 張錦松、韓光榮、張錦輝,“噪音振動控制”,高立圖書有限公司,2008年。
[15] B.S. Rahman and D.K. Lieu, “The Origin of permanent Magnet Induced Vibration in Electric Machines,” Journal of Vibration and Acoustics, Vol.113, pp. 476-481, 1991.
[16] E.G. Williams, J.D. Maynard and E. Skudrzyk, “Sound source reconstruction using a microphone array, Journal of Acoustical Society of America,“ Journal of Acoustical Society of America, Vol. 68, No. 1, pp. 340-344, 1980.
[17] T. Loyau, J.C. Pascal and P. Gaillard, “Broadb and Acoustic Holography Reconstruction from Acoustic Intensity Measurement. I : principle of the method,” Journal of Acoustical Society of America, Vol. 84, No. 5, pp. 1744-1750, 1988.
[18] B. Eck, “Fans: Design and Operations of Centrifugal, Axial-Flow and ross-Flow Fans”, Pergamon Press, N.Y., 1973.
[19] ANSI/AMCA Standard 210-99 (ANSI/ASHRAE 51-1999), “Laboratory Method of Testing Fans for Aerodynamic erformance Rating”, Air Movement and Control Association, Inc., 999.
[20] CNS 8753, “Determination of Sound Power Level of Noises for Fan, Blower, and Compressors”, Chinese National Standard, 1982.
[21] R. Bowerman and A. Acosta, “Effect of the Volume on Performance of Centrifugal Pump Impeller”, Trans. ASME, Vol. 79, pp. 1057-1069, 1957.
[22] D. Raj, and W.B. Swim, “Measurements of the Mean Flow Velocity and Velocity Fluctuations at the Exit of a F-C Centrifugal Fan Rotor”, Journal of Engineering for Power, Vol. 103, pp. 393-399, 1981.
[23] K. Morinushi, “The Influence of Geometric Parameters on F-C Centrifugal Fan Noise”, Journal of Vibration, Acoustic, Stress, and Reliability in Design, Vol. 109, pp. 227-234,1987.
[24] G. Huebner, ”Noise Generated by Centrifugal Fans”, Siemens- Zeitschrift, Vol. 8, pp. 145-155,1959.
[25] W.A. Smith, “Reducing Blade Passage Noise in Centrifugal Fans”, American Society of Heating, Refrigerating and Air-Conditioning Engineers Transaction Part II, Vol. 80, pp. 45-51, 1974.
[26] W. Neise, “Noise Reduction in Centrifugal Fans : A Literature Survey”, Journal of Sound and Vibration, Vol. 45, No. 3,pp. 375-403, 1976.
[27] W. Neise, “Review of Noise Reduction Methods for Centrifugal Fans”, Journal of Engineering for Industry, Vol. 104, pp. 151-161, 1982.
[28] L. Kondo and Y. Aoki, “Noise Reduction in Turbo Fans for Air Conditioners”, Technical Review-Mitsubishi Heavy Industries, Vol. 26, No. 3, pp.173-179, October 1989.
[29] L. Bommer, R. Grundmann, and K. Klaes, and C. Kramer, “Effect Blade Design on Centrifugal Fan Noise and Performance”, Noise Control Engineering, Vol. 42, No. 3, pp. 91-101, 1995.
[30] S. C. Lin, “A Novel F-C Centrifugal Fan Design for Improved Performance”, Department of Mechanical Engineering, Technical Report, Tennessee Technological University, 1982.
[31] M Ken., “The Influence of Geometric Parameters on F.C. Centrifugal Fan Noise”, Journal of Vibration, Acoustic, Stress, and Reliability in Design, Vol. 109, pp. 227-234, 1987.
[32] R. Bowerman, and A. Acosta, ”Effect of the Volume on Performance of a Centrifugal Pump Impeller”, Trans. ASME, Vol. 79, pp. 1057-1069, 1957
[33] H.Y. Zhang, Pinjala D., Navas O.K., Iyer M.K., Chan P.K., Liu X. P., Hayashi H. and Han J.B., ”Development of Thermal Solutions for High Performance Laptop Computers”, 2002 IEEE Inter Society Conference on Thermal Phenomena, pp. 433-440, 2002.
[34] T. Wright, “Centrifugal Fan Performance With Inlet Clearance”, ASME Journal of Engineering for Gas Turbines and Power, Vol. 106, pp. 906-912, 1984.
[35] T. Elholm, and E. Ayder, “Experimental Study of the Swirling Flow in the Volute of a Centrifugal Pump,” ASME, Journal of Turbomachinery, Vol. 114, pp. 366-372, 1992.
[36] D.V. Hope, and P.M. Padole, “Experiment and Theoretical Analysis of Stresses, Noise and Flow in Centrifugal Fan Impeller,” Journal of Mechanism and Machine ,Theory, Vol. 39, pp. 1257-1271, 2004.